IO-Link EMC Test Device – EMC Conformity Tests for IO-Link Masters

The IO-Link Interface Specification requires a specific test Device for the EMC test (see Annex H.2.2: Test of a Master), which must be connected to the Master during the EMC test. The IO-Link EMC Test Device fulfills these requirements and tests your IO-Link Master against the specified demands.

Do you want to test your IO-Link Master for EMC conformity?

The EMC Test Device provides reliable error statistics for the EMC conformity test of your Master.
Product Data Sheet

Functional Description

For the test, the test Device generates 8-bit random numbers, which are to be read as process data by the Master and written back to the test Device in the next cycle. The Device then checks whether the process data returned by the Master matches the data sent in the previous cycle and increments an internal error counter if this is not the case. The error counter is also incremented if a checksum error or a parity error is detected, or if a Master cycle is completely missing. The status of the error counter is displayed on a seven-segment display. Additionally, after the test is completed, the Master can read the error counter via IO-Link parameters. The IO-Link interface also allows the error levels of the individual error types to be read. The EMC Test Device is configurable. For example, the baud rate can be set via DIP switches.

EMC Test Device Features

  • Complies with the requirements of the V1.1.X IO-Link Interface Specification
  • All 3 COM rates are supported (DIP switches and IO-Link parameters)
  • Internal pseudo-random number generator
  • Error counters for parity, checksum, data, and timeout errors
  • Dual 7-segment display for operating mode and error status
  • Error levels are retrievable via IO-Link
  • Additional support for round-trip delay measurements
  • Total error count and maximum error count within a standardized group of M-sequences available separately via IO-Link. Two group sizes selectable per COM speed

Further test systems for your IO-Link Master project

In addition to the protocol test, the physical layer test and the EMC test are also required for a complete IO-Link certification (Test & Quality IO-Link Community). To achieve this goal with minimal effort, TEConcept offers additional diagnostics & test tools that can be used directly by members of the IO-Link Community for issuing the required certifications. For non-members, TEConcept, as an accredited IO-Link Competence and Test Center, handles the execution of the certification tests.

IO-Link Master Tester V1.1.3

IO-Link Master Tester

Test system for IO-Link Master manufacturers to create the manufacturer's declaration. Automatically performs the prescribed conformity tests according to IO-Link test specification V1.1.3 and generates a PDF test report. Recommended by the IO-Link Community.

TEConcept IO-Link Safety Master Tester for IO-Link Safety Masters

IO-Link Safety Master Tester

Test system for manufacturers of IO-Link Safety Masters — a mandatory prerequisite for safety assessment by notified bodies such as TÜV. Automatically transmits IFAK-approved test vectors and generates a PDF test report.

Contact

If you have any questions about the test Device for EMC conformity testing or its functions, please use our contact form. Our team will be happy to assist you.

Please note our privacy policy.